6—Editing Algorithms
ENSONIQ DP/Pro Reference Manual 9
9 Dual-Mono Gate
Level
Detector
Control
Left
L—Attack, Release/Hold
L—Lookahead
L—Threshold, Hysteresis, Attenuation
Left
Right
Output
Input
Level
Detector
Control
R—Attack, Release/Hold
R—Lookahead
R—Threshold, Hysteresis, Attenuation
Right
Description: Similar to the Stereo Gate, but allows independent processing of left and right channels.
Notes: Set the attenuation for the desired gating level. Minimize chatter by setting the hysteresis and
the hold time. The amount of hysteresis sets the dB difference between the (attack) threshold and the
release threshold. The hold time is the duration for which the source level must remain below the
threshold before the gate closes.
I/O Characteristics: Stereo-in, stereo-out
Parameter Name Ref Value Min Max Attributes
L-Thresh -20.0dB -99.0dB +0.0dB M
L-Hysteresis +10.0dB +0.0dB +99.0dB
L-Atten +40.0dB +0.0dB +99.0dB
L-Attack 10.0ms 50.0us 10.0sec
L-Release 100.0ms 50.0us 10.0sec
L-Hold 100.0ms 0.0us 10.0sec
L-Lookahead 0.0ms 0.0ms 20.0ms
R-Thresh -20.0dB -99.0dB +0.0dB M
R-Hysteresis +10.0dB +0.0dB +99.0dB
R-Atten +40.0dB +0.0dB +99.0dB
R-Attack 10.0ms 50.0us 10.0sec
R-Release 100.0ms 50.0us 10.0sec
R-Hold 100.0ms 0.0us 10.0sec
R-Lookahead 0.0ms 0.0ms 20.0ms
B=parameter has bi-polar range G=maximum gain limited by Set Max Gain System/MIDI parameter
H=high-frequency limit determined by system sample rate M=parameter has supplemental metered display
L=lowest frequency limited by Set Min Freq System/MIDI parameter T=parameter can be synchronized to system clock or MIDI clocks
Page view 62