Section 3 — Config Parameters
4 ENSONIQ DP/4+ Reference Manual
Selecting a Config Preset
In Select mode, you can select Config presets which will:
Reconfigure the DP/4+ inputs and outputs;
Change the signal routing between units; and
Load a new algorithm (and its saved parameters) into each of the four Units.
To select a Config preset:
1. Press {SELECT}, then {CONFIG}.
2. Move the Data Entry Knob. The Select LED flashes, indicating that you are previewing
presets. The display shows the available Config presets.
3. When the display is showing the preset you want to load, press {SELECT} again. This selects
the preset, and the Select LED stops flashing (solidly lit).
Editing a Config Preset
In Edit mode, you can select between the input configurations and edit their related parameters
(which contain other signal routing information) using the {<} and {>} buttons to select
parameters, and the Data Entry Knob to change the value of the active (flashing) parameter.
To edit a Config Preset:
1. Press the {EDIT} button.
2. If the yellow Config LED is not already on, press {CONFIG}. The display shows:
Parameter Number Input Config Select (flashing)
m m
oo
1 Source Config
1,2 > ABCD
The red LED display should indicate parameter 00, which is the Input Config Select parameter,
and the current config type should be flashing in the upper line of the LCD display (if not,
press {<} until this is the case).
3. If you move the Data Entry Knob now, you will select among the config types. There are
four different types of configs that can be edited:
1 source Config 2 source Config 3 source Config 4 source Config
When you stop moving the knob, the display momentarily shows:
oo
Updating
Config
The DP/4+ is now updated into the config showing on the display.
4. To edit the remaining config parameters, press the {>} button to scroll to other parameters,
and move the Data Entry Knob to change their values.
Note: Changing the config type, or editing some config parameters may cause a brief
interruption in the audio output. This will happen if you change the number of
sources, or if the mono/stereo output routing is different. This interruption is normal
and is required for the system to reconfigure its signal routing.