1 Source Config
1 Source Config
1,2 > ABCD
00 — 1 Source Config
The 1 Source Config arranges the DP/4+ as one giant multi-effects processor, using all four units
to process the same input signal. 1 Source Configs have two input select options, mono or stereo
(refer to parameter 01).
AB Input Select=
(1,2) Stereo
01 — AB Input Select Range: (1,2) Stereo or (1) Mono
Selects either a mono (Input 1) or stereo (Inputs 1 and 2) signal.
AB Unit Routing=
[A+B] parallel
02 — AB Unit Routing Range: serial, parallel, feedback1 or feedback2
Units A and B can be routed together in one of four different ways:
B
A
1
2
1
2
Parallel
1
2
B
1
2
A
Serial
Dry
Dry
1
2
B
1
2
A
Feedback
Wet
Feedback 1
DryDry
1
2
B
1
2
A
Feedback
Wet
Feedback 2
The feedback routings are similar to the serial routing, with the addition of a feedback signal.
The difference between Feedback 1 and Feedback 2 is how the dry signal is mixed into the wet
signal (as shown above). Note that the feedback signal is all wet, and that it is tapped before the
dry signal.