ENSONIQ DP/2 Specifications Page 126

  • Download
  • Add to my manuals
  • Print
  • Page
    / 199
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 125
Section 3 — Config Parameters
ENSONIQ DP/4+ Reference Manual 5
1 Source Config
oo
1 Source Config
1,2 > ABCD
00 — 1 Source Config
The 1 Source Config arranges the DP/4+ as one giant multi-effects processor, using all four units
to process the same input signal. 1 Source Configs have two input select options, mono or stereo
(refer to parameter 01).
o1
AB Input Select=
(1,2) Stereo
01 — AB Input Select Range: (1,2) Stereo or (1) Mono
Selects either a mono (Input 1) or stereo (Inputs 1 and 2) signal.
o2
AB Unit Routing=
[A+B] parallel
02 — AB Unit Routing Range: serial, parallel, feedback1 or feedback2
Units A and B can be routed together in one of four different ways:
B
A
1
2
1
2
Parallel
1
2
B
1
2
A
Serial
Dry
Dry
1
2
B
1
2
A
Feedback
Wet
Feedback 1
DryDry
1
2
B
1
2
A
Feedback
Wet
Feedback 2
The feedback routings are similar to the serial routing, with the addition of a feedback signal.
The difference between Feedback 1 and Feedback 2 is how the dry signal is mixed into the wet
signal (as shown above). Note that the feedback signal is all wet, and that it is tapped before the
dry signal.
Page view 125
1 2 ... 121 122 123 124 125 126 127 128 129 130 131 ... 198 199

Comments to this Manuals

No comments